The device is used for insulation of large photovoltaic systems up to AC 1000 V/DC 1500 V designed as IT systems. The measurement method specially developed for slow voltage fluctuations (MPP tracking) monitors the insulation resistance even in systems equipped with large solar generator panels where extremely high system leakage capacitances against earth exist due to interference suppression methods. Adaptation to system-related high leakage capacitances also occurs automatically.
The device generates locating current pulses required for insulation fault location. That allows the localisation of the insulation fault using permanently installed or mobile insulation fault locators.
The device is used for insulation of large photovoltaic systems up to AC 1000 V/DC 1500 V designed as IT systems. The measurement method specially developed for slow voltage fluctuations (MPP tracking) monitors the insulation resistance even in systems equipped with large solar generator panels where extremely high system leakage capacitances against earth exist due to interference suppression methods. Adaptation to system-related high leakage capacitances also occurs automatically.
The device generates locating current pulses required for insulation fault location. That allows the localisation of the insulation fault using permanently installed or mobile insulation fault locators.
Only device version isoPV1685P provide a locating current injector.
Type | Response value range | Supply voltage Us | Nominal system voltage Un | Art. No. |
---|---|---|---|---|
isoPV1685RTU-425 | 200 Ω…1 MΩ | DC 18…30 V | AC 0…1000 V/DC 0…1500 V | B91065603 |
isoPV1685P-425 | 200 Ω…1 MΩ | DC 18…30 V | DC 0…1500 V | B91065604 |
Name | Category | Size | Language | Timestamp | D-/B-Number |
---|---|---|---|---|---|
isoPV1685P | Manuals | 4.8 MB | EN | 2024/09/0505.09.2024 | D00007 |
isoPV1685P | Manuals | 4.9 MB | DE | 2024/09/0303.09.2024 | D00007 |
isoPV1685P | Datasheets | 2.0 MB | EN | 2024/09/0505.09.2024 | D00007 |
isoPV1685P | Datasheets | 2.0 MB | DE | 2024/09/0505.09.2024 | D00007 |
isoPV1685RTU - Modbus settings | Application note | 250.2 KB | EN | 2023/07/0606.07.2023 | |
isoPV1685RTU - Modbuseinstellungen | Application note | 252.9 KB | DE | 2023/07/0606.07.2023 | D00007 |
UKCA - isoXX1685 | Declarations of Conformity | 122.0 KB | 2023/06/1212.06.2023 | ||
Erneuerbare Energien: Photovoltaik | Market Segment Brochures | 2.0 MB | DE | 2023/06/1616.06.2023 | |
isoXX1685 | CE Declarations of conformity | 89.1 KB | 2023/06/1212.06.2023 | ||
Renewable energies: Photovoltaics | Market Segment Brochures | 2.0 MB | EN | 2023/06/1616.06.2023 | |
CAN communication for isoPV1685 | Manuals | 367.2 KB | EN | 2023/04/0505.04.2023 | D00007 |
isoPV1685RTU/isoPV1685P | Manuals | 2.5 MB | DE | 2023/04/0505.04.2023 | D00007 |
isoPV1685RTU/isoPV1685P | Manuals | 2.4 MB | EN | 2023/04/0505.04.2023 | D00007 |
isoPV1685/isoPV1685PFR Appendix A | Manuals | 494.6 KB | EN | 2019/05/1313.05.2019 | D00007 |
isoPV1685RTU/isoPV1685P | Datasheets | 627.9 KB | DE | 2023/04/0505.04.2023 | D00007 |
isoPV1685RTU/isoPV1685P | Datasheets | 645.5 KB | EN | 2023/04/0505.04.2023 | D00007 |
isoPV1685RTU/isoPV1685P | Datasheets | 520.2 KB | ES | 2023/04/0505.04.2023 | D00007 |
isoPV1685RTU/isoPV1685P | Quickstarts | 1.0 MB | DE | 2023/04/0505.04.2023 | D00007 |
isoPV1685RTU/isoPV1685P | Quickstarts | 1.0 MB | EN | 2023/04/0505.04.2023 | D00007 |