LINETRAXX® RCM420

The AC and pulsed DC sensitive residual current monitor RCM420-D (Type A) from Bender is designed for fault and residual current monitoring in earthed power supply systems (TN and TT systems) where an alarm is to be activated in the event of a fault, but disconnection must be prevented. In addition, the device can be used to monitor single conductors, such as PE conductors, N-PE connections and PE-PAS connections.

The prewarning stage (50…100 % of the set response value IΔn2) allow to distinguish between prewarning and alarm. Since the values are measured with measuring current transformers, the device is nearly independent of the load current and the nominal voltage of the system.

Questions? Contact us!

LINETRAXX® RCM420
LINETRAXX® RCM420

The AC and pulsed DC sensitive residual current monitor RCM420-D (Type A) from Bender is designed for fault and residual current monitoring in earthed power supply systems (TN and TT systems) where an alarm is to be activated in the event of a fault, but disconnection must be prevented. In addition, the device can be used to monitor single conductors, such as PE conductors, N-PE connections and PE-PAS connections.

The prewarning stage (50…100 % of the set response value IΔn2) allow to distinguish between prewarning and alarm. Since the values are measured with measuring current transformers, the device is nearly independent of the load current and the nominal voltage of the system.

Questions? Contact us!

Features

  • AC and pulsed DC sensitive residual current monitor Type A according to IEC 62020
  • r.m.s. value measurement (AC)
  • Two separately adjustable response values
  • Frequency range 42…2000 Hz
  • Start-up delay, response delay and delay on release
  • Restart function
  • Digital measured value display via LC display
  • Measured value memory for operating value
  • CT connection monitoring
  • LEDs: Power On, Alarm 1, Alarm 2
  • Internal/external test/reset button
  • Two separate alarm relays (one changeover contact each)
  • N/O or N/C operation and fault memory behaviour selectable
  • Password protection for device setting
  • Device self monitoring
  • Sealable transparent cover
  • Two-module enclosure (36 mm)
  • RoHS compliant
  • Push-wire terminal (two terminals per connection)

Applications

  • Residual current monitoring in earthed two, three or four conductor systems
  • Current monitoring of single conductors de-energised under normal conditions
  • Socket-outlet circuits for devices which are operated unattended for a long time and which may not fail
  • Alarm systems, safety devices
  • Air conditioning systems, EDP systems
  • Cooling equipment with valuable frozen goods
  • Canteen kitchens
  • Monitoring of earthed power supplies for stray currents
  • Impact on N conductors
  • Trace heating systems

LINETRAXX® RCM420 Variant(s)

TypeResponse range IΔnFrequency rangeSupply voltage US*Art. No.
RCM420-D-110 mA…10 A42…2000 HzDC 9,6…94 V /
AC 16…72 V, 42…460 Hz
B74014001
B94014001
RCM420-D-210 mA…10 A42…2000 HzDC 70…300 V /
AC 70…300 V, 42…460 Hz
B74014002
B94014002

* Absolute values
**(B7… = push-wire terminal / B9… = screw-type terminal)

Optional Accessories for LINETRAXX® RCM420

External measuring current transformers

TypeInside diameter (mm)Art. No.
CTAC20ø 20B98110005
CTAC35ø 35B98110007
CTAC60ø 60B98110017
CTAC120ø 120B98110019
CTAC210ø 210B98110020
WR70x175S70 x 175 mmB911738
WR115x305S115 x 305 mmB911739
WR150x350S150 x 350 mmB911740
WR200x500S200 x 500 mmB911763
WR70x175SP70 x 175 mmB911790
WR115x305SP115 x 305 mmB911791
WR150x350SP150 x 350 mmB911792
WR200x500SP200 x 500 mmB911793
WS20x3020 x 30B98080601
WS50x8050 x 80B98080603
WS80x12080 x 120B98080606

Accessories

TypeArt. No.
Mounting clip for screw mounting (one piece per device)B98060008
Mounting frame XM420B990994 

Downloads for LINETRAXX® RCM420

NameCategorySizeLanguageTimestampD-/B-Number
UKCA - RCM42x Declarations of Conformity 122.4 KB 2023/02/1313.02.2023
RCM42x CE Declarations of conformity 88.0 KB 2023/10/1919.10.2023
RCM420 Manuals 11.2 MB DE2024/09/0505.09.2024D00057
RCM420 Manuals 11.2 MB EN2024/09/0505.09.2024D00057
RCM420 Manuals 736.1 KB ES2019/05/1313.05.2019D00057
RCM420 Manuals 747.0 KB FR2019/05/1313.05.2019D00057
RCM420 Datasheets 10.5 MB DE2024/09/0505.09.2024D00057
RCM420 Datasheets 10.5 MB EN2024/09/0505.09.2024D00057
RCM420 Datasheets 339.1 KB ES2023/07/3131.07.2023D00057
RCM420 Datasheets 497.1 KB ZH2019/05/1313.05.2019D00057
XM420-Schnittstellenoptionen Datasheets 264.1 KB DE2019/05/1313.05.2019
XM420 interface options Datasheets 223.5 KB EN2019/05/1313.05.2019D00051
RCM420 Quickstarts 1.0 MB DE2024/09/0505.09.2024D00057
RCM420 Quickstarts 1.0 MB EN2024/09/0505.09.2024D00057
Changed variants of relays from goldplated to silver-plated contacts Technical information 166.3 KB EN2022/06/2727.06.2022
Geänderte Relaisvarianten von vergoldeten Kontakten auf versilberte Kontakte Technical information 166.3 KB DE2022/06/2727.06.2022